Set up the solver settings

This example shows how to set up the solver settings for a transient solution before an optimization using time varying convergence criterion method.

  1. In the TMG Correlation dialog box, select the OptimizationSolver Settings node.
  2. In the Correlation Times list, delete the correlation times that you do not want to consider for the optimization.

    You can also manually add correlation times by entering the time value to the list that comes from the sensor time points that you imported or defined on the Sensors page.

    To delete the time from the Correlation Times list, double-click the time and press Delete on your keyboard.

  3. From the Convergence Criterion Option list, select Time Varying to have a time-dependent convergence criterion.

    For a steady state solution if you set Convergence Criterion Option to Constant, provide just one value in the Convergence Criterion box.

  4. In the Convergence Criterion Option table, enter time-dependent convergence criterion values or use Import from File to automatically populate the table.
  5. In the Maximum Design Cycles box, type the maximum number of optimization cycle iterations, for example 2000.
  6. From the Optimization Algorithm list, select Method of Moving Asymptotes as an optimization algorithm.

    For more information, see Optimization algorithms.