Card 9 - IMMERSEDDUCTS Immersed Ducts Definition

This optional card defines the immersed ducts boundary conditions.

Parameters: KODE, N1, T1, T2, T3

KODE

KODE is the code IMMERSEDDUCTS (or 122)

N1

N1 is the IMMERSEDDUCTS card ID. Cards with the same ID reference the same Immersed Ducts boundary conditions.

T1 = NAME

T1 = NAME (or 1) specifies the Immersed Ducts simulation object name in T2.

T1 = FLUID_SELECTION

T1 = FLUID_SELECTION (or 2) specifies a selection of 1D fluid elements to which the Immersed Ducts simulation object is applied. The selection is represented by the group name T2.

T1 = HTC

T1 = HTC (or 3) specifies a heat transfer coefficient for the convection between the selected 1D fluid elements and the surrounding solid elements.

  • If the heat transfer coefficient is constant, then its value is specified in T2.
  • If the heat transfer coefficient is table dependent, then T2 is a table multiplier and T3 has the form Tn, for example, T25 where n is a table number referencing the TABTYPE or FIELDTYPE cards. The dependent variable on the TABTYPE card must be COND.
  • If the heat transfer coefficient is calculated using an expression, then T2 is an expression multiplier and T3 has the form En, for example, E25 where n is an expression number referencing the EXPRESSION card.

Code example


$ Immersed Ducts(1)                                                            
NAME2 Immerse Immersed Ducts(1)
NAME Immerse          1         10          1
IMMERSEDDUCTS 1 NAME "Immersed Ducts(1)"
IMMERSEDDUCTS 1 FLUID_SELECTION "Immersed Ducts(1)"
IMMERSEDDUCTS 1 HTC  1.000000E+08 0