Card 9 - IMMERSEDDUCTS Immersed Ducts Definition
This optional card defines the immersed ducts boundary conditions.
Parameters: KODE
, N1
, T1
,
T2
, T3
KODE
KODE
is the code IMMERSEDDUCTS
(or 122)
N1
N1
is the IMMERSEDDUCTS card ID. Cards with the same ID reference
the same Immersed Ducts boundary conditions.
T1 = NAME
T1 = NAME
(or 1) specifies the Immersed Ducts simulation object name
in T2
.
T1 = FLUID_SELECTION
T1 = FLUID_SELECTION
(or 2) specifies a selection of 1D fluid
elements to which the Immersed Ducts simulation object is applied. The selection is
represented by the group name T2
.
T1 = HTC
T1 = HTC
(or 3) specifies a heat transfer coefficient for the
convection between the selected 1D fluid elements and the surrounding solid
elements.
- If the heat transfer coefficient is constant, then its value is specified in
T2
. - If the heat transfer coefficient is table dependent, then
T2
is a table multiplier andT3
has the form Tn, for example, T25 where n is a table number referencing the TABTYPE or FIELDTYPE cards. The dependent variable on the TABTYPE card must be COND. - If the heat transfer coefficient is calculated using an expression, then
T2
is an expression multiplier andT3
has the form En, for example, E25 where n is an expression number referencing the EXPRESSION card.
Code example
$ Immersed Ducts(1)
NAME2 Immerse Immersed Ducts(1)
NAME Immerse 1 10 1
IMMERSEDDUCTS 1 NAME "Immersed Ducts(1)"
IMMERSEDDUCTS 1 FLUID_SELECTION "Immersed Ducts(1)"
IMMERSEDDUCTS 1 HTC 1.000000E+08 0