Exporting heat loads

Thermal Model Exchanger supports the Total Load and Flux types of Thermal Desktop Heat Load. It converts these entities into the Heat Load and Heat Flux types of Simcenter 3D Space Systems Thermal Thermal Loads respectively.

Thermal Model Exchanger (TMX) supports exporting constant, time-dependent, and temperature-dependent values and tables for thermal loads. You can also specify multipliers for the supported table types as either a constant value or a symbol. The combination of time and temperature-dependent values and tables are not supported. For those tables, TMX exports the first value of the table defined in Thermal Desktop and displays a warning in the export summary.

TMX supports Thermal Desktop Heat Load that are applied on 3D solid primitives, faces of a solid primitive, surface primitives, edges of a surface primitive, surfaces, edges, 2D elements, and element edges. Note that Thermal Desktop does not allow Heat Load applied on a mix of entities.

The following table lists the Simcenter 3D and corresponding Thermal Desktop Heat Load entities.

Heat Load location Selected Entities in Thermal Desktop Selected Entities in Simcenter 3D
Solid 3D solid primitive 3D elements
Surface Face(s) of a 3D solid primitive 3D element faces
2D primitive 2D elements
2D elements from a regular mesh
Edge Edge(s) of a surface primitive 2D element edges
Edge(s) of regular 2D elements

TMX does not support the Put heat load into Insulation nodes option of the Thermal Desktop Heat Load, and ignores it during the export process.