8000 - 8999 fatal messages

ID Message text and information
8000 Insufficient data on file MODLCF.
8001 Time value on file MODLCF < -99990.
8002 HTF AND SINK Cards are improperly ordered on file MODLCF.
8003 Error in TMG input file INPF: Element label <ID> on Card 9 too large.
8004 Error in TMG input file INPF: Only group names are allowed on INTERP Cards with the TDTHCON option.
8005 Error in TMG input file INPF: Element <ID> on Card 9 INTERP Card does not exist.
8006 Error in TMG input file INPF: Table no <number> does not exist.
8007 No conductance found between elements <ID> and <ID>.
8008 Start time is less than the lowest Start Position time defined in any Orbital Heating entity and the lowest time value defined in any time-varying Heat Load or Heat Flux entity. Start time < minimum time defined in radiation request or time dependent heat load.
8009 Start time > maximum time defined in radiation request or time dependent heat load.
8010 Table number <number> is a duplicate.
8011 Missing interpolation table variable type definition for table number <number>.
8012 Missing interpolation table data for table number <number>.
8100 Solid element <ID> has coincident nodes.
8101 Solid element <ID> has collinear nodes.
8102 Solid element <ID> has <integer> nodes associated to it. TMG supports only solid elements with 4, 6, or 8 nodes.
8103 Error in TMG input file INPF: Orthotropic material defined with nodes <IDs> has improper nodes.
8104 Error in TMG input file INPF: Orthotropic material defined with nodes <IDs> has improper directions.
8105 Error in solid element <ID>. Either orthotropic properties are improperly defined, or, more probably, material angles are either not defined or are improperly defined.
8110 Interpolation table number <number> not found for joint <ID>.
8111 Invalid interpolation table type for joint <ID>.
8112 Reverse side of transparent element <ID> is not defined.
8113 Reverse sides are not defined for <number> transparent elements: <list of IDs> ...
8114 Multiple spin requests have been specified with different spin axes. All spin requests in one model must have the same spin axis.
8115 The model only consists of elements which are not yet supported by the finite element method such as 0D lump mass, 1D beams, 2D shells with zero thickness. In such a configuration, a parallel run cannot be operated. Please revisit the solution configuration in order to perform the thermal solve in serial.
8200 TMG Security Error 2011 TMG License Has Expired or Security Violation. TMG Error 2011 - TMG license has expired or security violation.
8201 TMG User Count Exceeded for <name> Module. TMG user count exceeded for <name> module.
8202 TMG Security Error 2016- <number>. TMG security error 2016- <number>.
8203 TMG Security Error 2015 - Usercount Error <number>. TMG security error 2015 - usercount error <number>.
8204 Referenced node <ID> does not exist.
8205 Error writing on file MSGF.
8206 TMG Security Error 2031 Your TMG Installation has Expired. TMG security error 2031 your TMG installation has expired.
8207 TMG security error 2006 - contact TMG support. TMG security error 2006 - contact TMG support.
8208 TMG Security Error 2018 Corrupt Client Database. TMG security error 2018 corrupt client database.
8209 TMG security error 2013- <number> could not read TMG security files. TMG security error 2013- <number> could not read TMG security files.
8210 TMG security error 2013- <number> could not decode TMG security files. TMG security error 2013- <number> could not decode TMG security files.
8211 TMG security error 2017 invalid client database. TMG security error 2017 invalid client database.
8212 TMG security error 2020 unregistered client. TMG security error 2020 - unregistered client.
8213 Absolute value of free convection exponent <value> is > 5.0.
8214 TMG Security Error 2019 No Current License. TMG security error 2019 no current license.
8215 TMG Security Error 2020 Contact TMG Support. TMG security error 2020 contact TMG support.
8216 TMG Security Error 2012 Contact TMG Support. TMG security error 2012 contact TMG support.
8217 Error in <name> module.
8218 Error in readcont subroutine.
8219 Incorrect data type <integer> in GETPUT.
8220 Incorrect element no <integer> in GETPUT.
8221 GETPUT entered recursively, ielem= <integer> itype= <integer>.
8222 Unable to allocate array <integer> from FGETMEM2.
8223 Error in PUT routine, IARR= <integer> IEL= <integer> IEL2= <integer>.
8224 File <name> is being opened with the improper unit number <number> should be <number>.
8225 Articulation parameters, or an orbit, diurnal heating, or solar heating request must be defined with an articulation request.
8226 Meshing of the earth failed, possibly due to a low H/R value. Try using GPARAM 4 116 1 which activates an alternate earth meshing technique.
8227 Interpolation fails for element ID <ID> from table <number>.
8228 Failed to parse the following string for expression ID <ID>: <name> for BC or element selection group name: <name>.
8229 Unrecognized field or variable name <name> encountered for expression ID <ID>: <name> for BC or element selection group name: <name>.
8230 Expression evaluation failure for expression ID <ID>: <name> for BC or element selection group name: <name> occurring at time = <value>.
8231 Array number <number> is outside of the permitted range [2001-2500]
8232 Non-existent entity IDs referenced as function arguments in expressions
8233 No available array number is found in the range between <integer> and <integer>
8234 Failed to copy file <name> to <name> with error code <number>
8235 The table <number> has an option LOG_LINEAR. However, the independent variable (argument) <value> is negative that is not a valid value for the log function.
8236 The table <number> has an option LINEAR_LOG. However, the dependent variable (function) <value> is negative that is not a valid value for the log function.
8237 The table <number> has an option LOG_LOG. However, the independent variable (argument) <value> is negative that is not a valid value for the log function.
8238 The table <number> has an option LOG_LOG. However, the dependent variable (function) <value> is negative that is not a valid value for the log function.
8239 The number of spatial dimensions for the table <number> is one. For Delaunay interpolation method, at least two spatial dimensions must be provided.
8240 There are no values specified for the table <number>. Please specify at least one value.
8241 The specified number <value> for the fraction of all points for the table <number> is too low. Please specify a larger number.
8242 The number of spatial variables <integer> is incorrect for the table <number>. Please check and correct this table.
8243 There are more than one non-spatial variables specified for the table <number>. Please specify no more than one non-spatial variable.
8244 There are fatal errors in the autoconnected stream topology. Please see the above messages for more information.
8245 There are fatal errors in the parallel run domain decomposition. Please see the above messages for more information.
8801 M=256 obsolete restart option - please use M=0 option instead.
8802 Error in TMG input file INPF: Missing title Card.
8803 File CHKPNT is present, analysis cannot proceed. Please delete or rename this file.
8804 File INPF not present in run directory, analysis cannot proceed.
8805 No machines are available to run <name> in parallel. Run command mpdboot; or mpd on the primary machine and mpd -h hostname -p port_number on the remote machines to set up the machine chain.
8806 A machine file is given but no machines in the file are available to run <name> in parallel. Double check the machines in the file and make sure that smpd/mpd processes are running and chained to the primary machine if on unix/linux. The machine file name is <name>.
8807 A machine file is given but the file is not accessible. Thus no machines are available to run <name> in parallel. The specified machine file name is: <name>.
8808 TMG tries to filter the machines from the given machine file and writes to a temporary machine file in the run directory to run <name> in parallel. However, the output file cannot be opened to write the machines in the run directory. The temporary output file name is: <name>. The given input machine file name is: <name>.
8809 When attempting to run <name> in parallel, MPI was unable to connect to the primary machine without prompting for user login credentials. Please use mpiexec -register or equivalent command on the primary machine and on all other machines in your machine file. Then reattempt the run. The primary machine is the machine where this TMG run was launched and TMG files are stored. The primary machine name in this TMG run is: <name>. The specified machine file name is: <name>.
8810 No machine file can be found! To run <name> in parallel on this platform, a machine file must be specified in which participating machines are listed. If this file is not given in INPF, TMG tries to open a default machine file in the following order: 1) mayampi.hosts in the local run directory; 2) $SDRC_TMG/if/tmgmpi.hosts. Neither of above exists.
8811 A Fortran user-written subroutine was found, and the PARAM USERDLL option was also specified. This combination requires double precision. Please ensure that the specification: DOUBLE PRECISION T(*),TIME,DT is present in your user-written subroutine.
8813 PARAM ANADOMDEC/DOMDEC/RADDOMDEC option is on but neither mayampi.hosts nor tmgdomdec.setup file is provided in the run/solution directory. Please run the parallel machine validation tool to have file mayampi.hosts written automatically.
8814 Error retrieving data from table <number>. Either the table has no entries or has invalid dependent or independent variables.
8815 View Factors GPU option in Parallel Configuration File must be activated.
8990 More than <integer> conductances in module CONN2.