15500 - 15999 warning messages

ID Message text and information
15501 Could not associate cyclic zone <name> to <name>.
15502 Cyclic zone <name> has no eligible elements.
15503 Detected a target node that belongs to a shell element as well as to a non-shell element.
15504 Could not associate thermal zone <name> to <name>.
15505 Could not associate flow zone <name> to <name>.
15506 Thermal zone <name> has no eligible elements.
15507 Flow zone <name> has no eligible elements.
15508 Symmetry zone <name> used for mapping overrides the axis defined as FEM axisymmetric extension.
15509 Symmetry zone <name> used for mapping contains axisymmetric meshes that have been overriden.
15510 Could not associate symmetry zone <name> to <name>.
15511 Symmetry zone <name> has no eligible elements.
15512 Unable to determine the thickness for the gradient pair (<ID>,<ID>).
15513 Could not associate transverse grad zone <name> to <name>.
15514 Transverse grad zone <name> has no eligible elements.
15515 Output is requested for structural solver(s) that expect temperature gradient results on nodes. The transverse grad target zone <name> only contains elements. No nodal values will be mapped for this zone.
15516 Output is requested for structural solver(s) that expect temperature gradient results on elements. The transverse grad target zone <name> only contains nodes. No elemental values will be mapped for this zone.
15517 Unsupported element type <type>.
15518 Unsupported node card.
15519 Unsupported element card.
15520 Hydraulic element found.
15521 Field data are not available at time <value>.
15522 Unsupported unit system.
15523 Source model contains non-axisymmetric meshes. Regular mapping will be applied.
15524 Source model contains inconsistent axisymmetric meshes with variable axis coordinates and/or segment numbers. Regular mapping will be applied.
15525 Source model contains axisymmetric meshes with unsupported axis values. The only supported axis are OX, OY, OZ. Regular mapping will be applied.
15526 Source model contains elements that do not all belong to a single plane containing the axis. Regular mapping will be applied.
15527 Source model does not have an axisymmetric extension. Regular mapping will be applied.
15528 No results of the requested type are found.
15529 Source alignment points MAP <ID> and MAP <ID> are too close to each other.
15530 Target alignment points MAP <ID> and MAP <ID> are too close to each other.
15531 Source and target alignment point sets are not similar.
15532 The bun file to append to already contains results for the some of the nodes. Those results will be ovewritten by the new mapping results. Here are some of those nodes:
15533 Transverse gradient values are currently not supported with TMG input files and have been omitted from the <*.gtempf> and <*.tempf> files.
15534 Transient output times are not specified. Mapping will be done at all printout times.
15535 Source data are not available at time <value>.
15536 The requested output time <value> is outside the range of the source file. The closest source time data were used for mapping.
15537 Field data are not available at the exact time <value>.Instead using the data at time <value>.
15538 Unsupported parameter <name>.
15539 Unsupported parameter <name> and value <name>.
15540 The source environment <name> is different from the target environment <name>. This may lead to wrong mapping results and should be avoided.
15541 The target model contains mixed order elements. The current value of the MIXED_ORDER_OPTION in fldmap.prm file in the run directory is either OFF or NO_RESULTS and therefore no mapped temperature bun file has been created. To create the bun file with results on all nodes, set the MIXED_ORDER_OPTION to MIXED_ORDER. To create the bun file with the mixed order elements displayed as linear elements, set the MIXED_ORDER_OPTION to LINEAR.
15542 The target model contains mixed order elements. The current value of the MIXED_ORDER_OPTION in fldmap.prm file in the run directory is either LINEAR or ON and therefore the mixed order elements are represented as linear elements in the mapped temperature bun file. To create the bun file with results on all nodes, set the MIXED_ORDER_OPTION to MIXED_ORDER.
15543 Invalid target model. It does not seem to have a mesh.
15544 No results of <type> type are found in source file.
15545 The alignment translation based on MAP1 points would break source model axisymmetry. To avoid this, no translation is done for the radial component.
15548 The <Append Results> function is enabled, but the requested output times are different from those in the file to append to. The results in the file to append to will be interpolated to the requested output times.
15549 The bun file to append to already contains results for the following nodes. Those results will be ovewritten by the new mapping results.
15550 The alignment translation based on Source Model Mapping simulation object would break source model axisymmetry. To avoid this, no translation is done for the radial component.
15551 For the Source Model Mapping simulation object, "Axis and Angle" method is selected and a non-zero angle is defined. However, no Rotation Axis is defined. Rotation transformation will be ignored for this mapping solution. Please revise the SO dialog in the UI and define a rotation axis if Rotation transformation is desired.
15552 The mapping geometry source file tmg50.h5 does not exist. However, the source model is of finite element type. Make sure that the source file tmg50.h5 is present in the mapping source directory: <name>.