7. Create the design variables.
You will use the multiplier and substitution methods to create design variables from the boundary condition parameters that are present in the correlated solution.
- In the TMG Correlation dialog box, select the node.
- In the Parameters and Expressions group, from the Type list, make sure that Parameters is selected.
- Expand the Filter subgroup, and select the Source Type check box.
- From the Source Type list, select Heat Load.
- Click Filter to only display the heat load sources in the Parameter and Expression table.
- From the Parameters and Expressions table, select Heat Load.
- In the Design Variable Definition group, from the Design Variable Method list, select Substitution to replace the Heat Load by a design variable.
- In the Design Variable Name box, type DV1_Heat_Load.
- Click Add Design Variable to add the DV1_Heat_Load design variable to the active thermal correlation analysis.
- In the Filter group, from the Source Type list, make sure that Contact Thermal Coupling is selected.
- Click Filter to only display the contact thermal coupling sources in the Parameters and Expressions table.
- From the Parameters and Expressions table, select Total Conductance.
- From the Design Variable Method list, select Multiplier to multiply the parameter by a design variable.
- In the Design Variable Definition group, in the Design Variable Name box, type DV2_antena_bus_TCTC_Total_Conductance.
- Click Add Design Variable to add the design variable to the active thermal correlation analysis.
- From the Parameters and Expressions table, select Heat Transfer Coefficient.
- In the Design Variable Definition group, in the Design Variable Name box, type DV3_walls_mass_TCTC_Heat_Transfer_Coefficient.
- Click Add Design Variable to add the design variable to the active thermal correlation analysis.
- From the Parameters and Expressions table, select the two Conductance per Length parameters.
- In the Design Variable Definition group, in the Design Variable Name box, type DV4_panel_bus_conductance.
- Click Add Design Variable to add the design variable to the active thermal correlation analysis.