Wire screens correlation
The flow solver computes the head loss coefficient for wire screens using the free area ratio of the studied geometry.
For wire screens the following correlation applies:
- A0 is the area of a single orifice.
- AFS is the area of the free stream.
- is the free area ratio.
The following assumption applies:
- Red > 103.