Wire screens correlation

The flow solver computes the head loss coefficient for wire screens using the free area ratio of the studied geometry.

For wire screens the following correlation applies:

  • A0 is the area of a single orifice.
  • AFS is the area of the free stream.
  • is the free area ratio.

The following assumption applies:

  • Red > 103.