Exporting heaters and heat loads

Thermal Model Exchanger 2.0 now supports exporting heaters with sense temperature selection from Thermal Desktop as thermal loads with thermostats or active heater controllers in Simcenter 3D Space Systems Thermal, and allows more options for heat load export.

Exporting heaters

Using Thermal Model Exchanger (TMX), Heaters with a sense temperature selection are now exported in Simcenter 3D as Thermal Loads with a modelling object of type:

  • Thermostat when Proportional is set to Off in Thermal Desktop.
  • Active Heater Controller with Proportional type when Proportional is set to On in Thermal Desktop.

Exporting heat loads

TMX now supports the following enhancements for exporting heat loads from Thermal Desktop into Simcenter 3D:

  • Exporting constant, time-dependent, and temperature-dependent values and tables for thermal loads.
  • Specifying multipliers for the supported table types as either a constant value or a symbol.