NEVADA output format

The REFORM module can transform the conductance-capacitance model to NEVADA format.

If a Card 9 PARAM NEVADA is present, a NEVADA model is written in the nevada.ren file.

  • Lump mass and beam elements are ignored.
  • Triangular planar elements with emissivities are transformed into NEVADA triangle surfaces.
  • Quadrilateral planar elements with emissivities are transformed into NEVADA quadrilateral surfaces.
  • The default surface normal is IN. If the reverse side of an element is created with a Card 9 REVNODE and the same radiative surface properties, the surface normal is BOTH.
  • Each NEVADA surface label is assigned the corresponding TMG element label.
  • In your CAE software you can create ELLIPSE, SPHERE, CYLINDER, CONE, PARABOLID and OFFSET PARABOLOID surface types. In order to do this, generate a mapped mesh using higher order elements on an ellipse, sphere, cylinder, cone or paraboloid. Make the mesh. However, it is imperative that the mesh including the midside nodes lines up with latitudes and longitudes of the underlying surface, otherwise the elements will be translated to either a TRIANGLE, QUADRILATERAL, or POLYGON surface types.
  • The orientation of the surfaces follows the standard TMG right hand rule convention, if the nodes are specified in a counterclockwise order, the element normal faces the viewer.