MODLCF
The MODLCF file is a condensed version of the MODLF file after addition of the Card 9 model parameters, element merging, substructuring, and combining of heat loads, capacitances, and conductances.
The format of MODLCF is identical to that of MODLF, with the following exceptions:
- For capacitances,
VAL1 =capacitance value,VAL2 = 1always. - MODLCF contains the additional capacitances, conductances, element sink temperatures, and heat loads specified on Card 9 XCOND, XCAP, SINK, and QNODE cards. The Card 9 XCOND
1WAYCconductance is written with the mnemonic1WC, and the1WAYRconductance is written with the mnemonic1WR. - There is only a single RDF card present at the beginning of the file.
- A series of time cards with
MNM = TIM,VAL1 =time value are written at the end of the file. These contain the time values specified on Card 9 QNODE and Card 6e radiation heat load requests. - All elements in the model are assigned a capacitance value with a
MNM = CAPcard, which may be zero. - For merged elements follower conductances
MNM = FOLare created, unless the Card 9 PARAMNOMRECOV option is specified. - Elements that have been eliminated with Card 8 and Card 9 PARAMSUBSTR substructuring and whose temperatures are to be calculated by the recovery process are set to be constant temperature sink elements
MNM = SNKwith a temperature of-1.E30.
Sink element temperatures
MNM = SNK
I = element
J = blank
VAL1 = temperature of the sink element
VAL2 = time when temperature occurs
Follower conductances
MNM = FOL
I = element whose temperature is to be followed
J = element whose temperature follows that of element I
