MODLCF
The MODLCF file is a condensed version of the MODLF file after addition of the Card 9 model parameters, element merging, substructuring, and combining of heat loads, capacitances, and conductances.
The format of MODLCF is identical to that of MODLF, with the following exceptions:
- For capacitances,
VAL1 =capacitance value,VAL2 = 1always. - MODLCF contains the additional capacitances, conductances,
element sink temperatures, and heat loads specified on Card 9 XCOND, XCAP, SINK, and
QNODE cards. The Card 9 XCOND
1WAYCconductance is written with the mnemonic1WC, and the1WAYRconductance is written with the mnemonic1WR. - There is only a single RDF card present at the beginning of the file.
- A series of time cards with
MNM = TIM,VAL1 =time value are written at the end of the file. These contain the time values specified on Card 9 QNODE and Card 6e radiation heat load requests. - All elements in the model are assigned a capacitance value with a
MNM = CAPcard, which may be zero. - For merged elements follower conductances
MNM = FOLare created, unless the Card 9 PARAMNOMRECOV option is specified. - Elements that have been eliminated with Card 8 and Card 9 PARAMSUBSTR substructuring
and whose temperatures are to be calculated by the recovery process are set to be
constant temperature sink elements
MNM = SNKwith a temperature of-1.E30.
The thermal solver removes the Oppenheim elements created for expanded elements. from the MODLCF file. This does not affect the results, but improves performance by reducing the number of elements, the number of follower conductances, and the size of the MODLCF file.
Sink element temperatures
MNM = SNK
I = element
J = blank
VAL1 = temperature of the sink element
VAL2 = time when temperature occurs
Follower conductances
MNM = FOL
I = element whose temperature is to be followed
J = element whose temperature follows that of element
I